Power Load Chart

UPS LOAD

DEVICE

PC’s with 15’ monitor
PC’s with 17’ monitor
DOT Matrix Printer
Inkjet Printer
Laserjet Printer
CFL Bulbs
WATTAGE

225
350
140
75
840
11 to 21
VA RATINGS

275-300
425
175
100
1050
20 to 30

In the case of Bio medical equipments and certain specific instruments, VA rating should be calculated based on the actual specifications.

INVERTER LOAD

Incandescent bulbs
Tubelights
DOT Matrix Printer
Fans
TV
Stereo Systems
Mixer/ Blender/ Juicer
Electric Iron
40/60/100
40
60
100-200
50-100
450
450
50/75/125
60-70
90
125-190
70-150
600
700

SINE WAVE INVERTER LOADS

Refrigerator
Air Conditioners
Vacuum Cleaner
Air Coolers
225-400
1500-2500
700
170-250
350-700
2500-4000
1100
260-400

TIPS:
  1. UPS/Stabilizer rating should be 20-25% higher than the total load to avoid UPS tripping on starting.
  2. For Semi-inductive and inductive loads, UPS rating should be 50% higher and also the battery capacity should be sufficiently high, to take care of the high current flow.